Description
The DD6-362 monoclonal antibody specifically recognizes AXL which is also known as Adhesion related kinase (ARK), JTK11, Tyro7, or Tyrosine-protein kinase receptor UFO (UFO). Tyro-3, AXL, and Mer (MerTK) constitute the TAM subfamily of receptor tyrosine kinases (RTK). AXL is a single-pass type I transmembrane glycoprotein comprised of an extracellular region with two immunoglobulin (Ig)-like domains and two fibronectin type III (FNIII) domains, a transmembrane segment and a conserved intracellular tyrosine kinase domain. AXL is variably expressed by multiple cell types including monocytes, macrophages, dendritic cells, NK cells, platelets, endothelial cells, vascular smooth muscle cells, and fibroblasts. AXL binds to the vitamin K-dependent Growth arrest-specific protein 6 (Gas6) through its extracellular Ig-like domains. Ligand binding leads to receptor dimerization, and autophosphorylation of tyrosine residues within the cytoplasmic AXL domains. This results in the activation of downstream signaling pathways that control cellular adhesion, aggregation, phagocytosis/efferocytosis, proliferation, survival, and migration. Through these activities, AXL plays major roles in development, the regulation of hematopoiesis and immunity, and ensures the integrity of the vascular system. Abnormal expression of AXL has been observed in various cancers and myeloproliferative disorders and by tumor cell lines.
BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application. For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.
1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
3. For U.S. patents that may apply, see bd.com/patents.
4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
8. An isotype control should be used at the same concentration as the antibody of interest.
9. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.