Hamilton, 243104, OxyFerm FDA Arc 425

The OxyFerm FDA Arc polarographic DO sensors combines the hygienic design of the OxyFerm dissolved oxygen product line with the advantages of Arc technology for analog and digital communication directly from the sensor.
Catalog Number: 243104
Pricing

Send a RFQ.

View RFQ List
Manufacturer's Pagewww.hamiltoncompany.com/sensors/dissolved-oxygen-sensors/oxyferm-fda/oxyferm-fda-arc?part-number=243104
Description
The OxyFerm FDA Arc is an electrochemical oxygen sensor designed for processes with high demands for hygiene, including pharmaceutical, biotechnology, and food & beverage production. It is available with either a 12 mm or 25 mm (XL) shaft diameter, offering increased versatility through optional accessories.
Equipped with a special rounded FDA-approved membrane to prevent gas bubble accumulation, the sensor boasts a robust construction compatible with steam sterilization, autoclaving, and CIP cleanings. This wide measuring range sensor provides reliable dissolved oxygen monitoring in challenging environments.
Specifications

General

Sensor FamilyOxyFerm FDA
Wetted PartsStainless Steel 1.4435; EPDM (Ethylene propylene elastomer); FKM (Fluorocarbon Elastomer); VMQ (Silicone elastomer); See compliance details in Material Specification document
Electrical ConnectorVP8
Measuring Range10 ppb to 40 ppm (DO) or 0.2 to 1000 mbar (pO₂)
ElectrolyteOxylyte
Accuracy at 25 °C± 2%
Drift at Room Temperature< 1% per week
Membrane CapFDA
Oxygen ConsumptionCa. 20 ng/h in air at 25 °C
Temperature SensorNTC 22 kOhm
Configurable ValuesDissolved oxygen (DO): mbar,%-sat,%-vol, µg/l ppb, mg/l ppm; Temperature: °C, °F, K
Surface Quality of SteelRa < 0.4 µm (N5)
Electrode systemSilver platinum combination
Analog Interface 14 to 20 mA for DO, programmable
Analog Interface 24 to 20 mA for Temp., programmable
Analog Interface 1 and 2Galvanically not isolated; pulse width modulation 3.5 kHz
Baud Rate4800, 9600, 19200, 38400, 57600, 115200 Bd
Polarization Voltage and Time-670 ± 50 mV, ≥ 2 hours
Operating Voltage7 to 30 VDC max. 150 mW
Serial NumberYes
Response Timet98% < 60 s at 25 °C
CertificateYes, with parameter settings and materials used
ATEX ApprovalNo
IECEx ApprovalNo
Diameter12 mm
AutoclavableYes
Steam SterilizableYes
CIPYes
Operating Temperature RangeAnalog interface: 0 to 110 °C; Digital interface: 0 to 130 °C
Pressure Range bar g0 to 4 bar
Max. CO₂ Partial Pressure0.01 bar
Required Flow≥ 0.03 m/s
Automatic PolarizationYes, max. 2 hours stabilisation time